Atmospheric, splash and immersed: three coating problems

Updated 12 Oct 2026

The same steel structure can sit in three corrosion environments at once. Each one loads the coating differently, and one system rarely covers all three well.

A jetty pile, an offshore platform leg or a ship's hull all cross more than one environment. The part above the waterline, the part washed by waves and the part permanently submerged see different corrosion drivers, and a coating that performs well in one of them can fail early in another.

One structure, three environments

Standards such as ISO 12944 split the world into atmospheric corrosivity categories (C1 to C5, and CX for extreme cases) and immersion categories (Im1 to Im3). A single structure can span several of them along its height, so the specification is written zone by zone rather than as one flat system.

The atmospheric zone

  • What drives attack. Oxygen and moisture are both plentiful, but the dominant factors are airborne chlorides near the coast, sulphur compounds in industrial air, and repeated wet-dry cycling.
  • What the coating must do. Withstand UV and thermal cycling without chalking or cracking, and keep a barrier against chlorides. This is why the topcoat matters more here than anywhere else.

The splash and tidal zone

  • What drives attack. Alternating immersion and drying keeps the surface oxygen-rich while salt never fully rinses away. Mechanical action from waves and floating debris adds abrasion and impact.
  • What the coating must do. Survive the highest corrosion rates in the structure. Thick, tough films are the base, and on offshore work glass-flake or similar abrasion-resistant layers are common.

The immersed zone

  • What drives attack. Oxygen reaches the surface mostly by diffusion through water, so the rate is often lower than in the splash zone. Biological activity and, where cathodic protection is used, alkaline conditions at the steel surface become the governing factors.
  • What the coating must do. Resist long-term water uptake, stay compatible with cathodic protection and, on hulls, work with the antifouling scheme.

What actually changes in the specification

Dry film thickness, primer type, number of coats and topcoat chemistry all shift between zones. A zinc-rich primer that is essential in the splash zone may be a poor choice where cathodic protection is applied, and a soft antifouling topcoat makes no sense above the waterline. Treating the whole structure as one environment usually means over-specifying one part and under-protecting another.

Where zones meet, the boundaries are not sharp, and a good specification widens the transition so that neither system is left vulnerable. Publicly available manufacturer materials list suitable systems per category; specific parameters should always be confirmed against the latest edition of the manufacturer's technical data sheet (TDS).

Sources

  • ISO 12944-2, public scope on corrosivity categories (C1–C5, CX) and immersion categories (Im1–Im3)
  • ISO 12944-5, public scope on protective paint systems for steel structures
  • Publicly available manufacturer materials on heavy-duty systems for atmospheric, splash and immersed zones

Articles are compiled by RichTech from publicly available manufacturer materials and field practice, for selection reference only; the latest official technical data sheets (TDS) prevail.

Not sure which product fits? Tell us the substrate and service conditions

Share your substrate, corrosivity category and target service life — we will come back with a coating system and quantity estimate.

Contact us