<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom">
<channel>
<title>RichTech Coatings — coating insights</title>
<link>https://www.rich-tech-coatings.com/en/news</link>
<description>Selection guides, technical explainers, application notes and industry updates on marine and industrial protective coatings.</description>
<language>en</language>
<atom:link href="https://www.rich-tech-coatings.com/feed.xml" rel="self" type="application/rss+xml"/>
<item><title>Dew point and steel temperature: the window you can spray in</title><link>https://www.rich-tech-coatings.com/en/news-dew-point-steel-temperature-application-window</link><guid isPermaLink="true">https://www.rich-tech-coatings.com/en/news-dew-point-steel-temperature-application-window</guid><pubDate>Tue, 13 Oct 2026 08:00:00 +0800</pubDate><category>Application</category><description>Three degrees above dew point is only the start. What the window really rules out, how to measure it on site, and why the coldest hour decides the schedule.</description></item><item><title>Atmospheric, splash and immersed: three coating problems</title><link>https://www.rich-tech-coatings.com/en/news-atmospheric-splash-immersed-zone-coatings</link><guid isPermaLink="true">https://www.rich-tech-coatings.com/en/news-atmospheric-splash-immersed-zone-coatings</guid><pubDate>Mon, 12 Oct 2026 08:00:00 +0800</pubDate><category>Technical</category><description>The same steel structure can sit in three corrosion environments at once. Each one loads the coating differently, and one system rarely covers all three well.</description></item><item><title>How carbon intensity rules are reshaping hull coating decisions</title><link>https://www.rich-tech-coatings.com/en/news-carbon-intensity-rules-hull-coating-decisions</link><guid isPermaLink="true">https://www.rich-tech-coatings.com/en/news-carbon-intensity-rules-hull-coating-decisions</guid><pubDate>Sun, 11 Oct 2026 08:00:00 +0800</pubDate><category>Industry</category><description>Carbon rules and fuel penalties are pushing owners to treat hull coatings as a fuel-saving asset rather than a maintenance line item.</description></item><item><title>Why 25-year coating specifications are becoming the norm</title><link>https://www.rich-tech-coatings.com/en/news-longer-service-life-coating-spec-trend</link><guid isPermaLink="true">https://www.rich-tech-coatings.com/en/news-longer-service-life-coating-spec-trend</guid><pubDate>Sat, 10 Oct 2026 08:00:00 +0800</pubDate><category>Industry</category><description>Newbuild and industrial tenders increasingly ask for 25 years to first major maintenance. What that shift changes in system selection, film build and shop-floor practice.</description></item><item><title>How to choose a primer for C5-M steel structures</title><link>https://www.rich-tech-coatings.com/en/news-c5m-steel-primer-selection</link><guid isPermaLink="true">https://www.rich-tech-coatings.com/en/news-c5m-steel-primer-selection</guid><pubDate>Fri, 09 Oct 2026 08:00:00 +0800</pubDate><category>Selection guide</category><description>Zinc-rich epoxy, zinc silicate or zinc-free epoxy? How to pick the primer layer for C5-M and offshore steel by service life, surface prep and recoat window.</description></item><item><title>Zinc-rich epoxy vs inorganic zinc silicate</title><link>https://www.rich-tech-coatings.com/en/news-zinc-rich-epoxy-vs-inorganic-zinc-silicate</link><guid isPermaLink="true">https://www.rich-tech-coatings.com/en/news-zinc-rich-epoxy-vs-inorganic-zinc-silicate</guid><pubDate>Thu, 08 Oct 2026 08:00:00 +0800</pubDate><category>Selection guide</category><description>Both are zinc primers, but they behave very differently on site. A side-by-side comparison of preparation demands, curing, recoat windows and where each one wins.</description></item><item><title>Volume solids: converting wet film to dry film thickness</title><link>https://www.rich-tech-coatings.com/en/news-wet-film-dry-film-volume-solids</link><guid isPermaLink="true">https://www.rich-tech-coatings.com/en/news-wet-film-dry-film-volume-solids</guid><pubDate>Wed, 07 Oct 2026 08:00:00 +0800</pubDate><category>Technical</category><description>Why the same 200 µm specification can mean different paint consumption on two products, and how volume solids drives your material estimate and cost per square metre.</description></item><item><title>Recoat intervals: the window most projects get wrong</title><link>https://www.rich-tech-coatings.com/en/news-recoat-interval-and-overcoating-window</link><guid isPermaLink="true">https://www.rich-tech-coatings.com/en/news-recoat-interval-and-overcoating-window</guid><pubDate>Tue, 06 Oct 2026 08:00:00 +0800</pubDate><category>Application</category><description>Applying the next coat too early causes solvent entrapment; too late causes intercoat adhesion failure. How to read recoat tables and plan around weather and yard logistics.</description></item><item><title>Surface preparation grade and profile: two different things</title><link>https://www.rich-tech-coatings.com/en/news-surface-preparation-grade-and-profile</link><guid isPermaLink="true">https://www.rich-tech-coatings.com/en/news-surface-preparation-grade-and-profile</guid><pubDate>Mon, 05 Oct 2026 08:00:00 +0800</pubDate><category>Application</category><description>Sa 2½ is a cleanliness grade; roughness is a separate measurement. Both have to be specified, checked and recorded — most adhesion failures start here.</description></item><item><title>What the MIO intermediate coat actually does</title><link>https://www.rich-tech-coatings.com/en/news-mio-intermediate-coat-purpose</link><guid isPermaLink="true">https://www.rich-tech-coatings.com/en/news-mio-intermediate-coat-purpose</guid><pubDate>Sun, 04 Oct 2026 08:00:00 +0800</pubDate><category>Technical</category><description>Micaceous iron oxide is not a filler. It changes how the film behaves under UV, in thick build-ups and at edges — and it is often the layer that decides whether the system survives.</description></item>
</channel>
</rss>
